video
1535nm 20uJ 2KHz Eye-Safe Pulsed Erbium Glass Laser Module

1535nm 20uJ 2KHz Eye-Safe Pulsed Erbium Glass Laser Module

Model: JTBY20μJ
Operating Wavelength: 1535±5 nm
Pulse Energy: 20μJ
Pulse Width: 5-8ns
Repetition Rate:2Khz
Spot Diameter: 0.2mm
Beam Divergence Angle:≤15mard
Size: 17×8×7mm(Without connector)
Operating Temperature: -45℃-65℃
Storage Temperature: -55℃-85℃
Driving Parameters: 2 V,3A,≥0.3ms
Weight:≤6g

Chat Now
Product Introduction

Products overview

The 1535nm 20μJ 2kHz erbium glass laser is a compact high‑repetition‑rate pulsed laser source engineered for LiDAR, high‑frequency laser ranging and small‑form electro‑optical sensing hardware. Capable of running at up to 2 kHz, this unit outputs 2000 laser pulses each second. It fits use‑cases that demand frequent target sampling and fast ranging update cycles, where high single‑pulse energy is not the primary design goal.

Packing 20μJ pulse energy alongside a 5‑8ns pulse width, the module measures 17 × 8 × 7 mm and weighs no more than 6 grams. It serves as a ready‑to‑implement transmitter option for OEM ranging builds working under tight size, weight and power (SWaP) limits.

Why 2kHz for High-Frequency Laser Ranging?

In pulsed laser ranging and LiDAR systems, repetition rate determines how frequently the transmitter can generate a new laser pulse for measurement. Unlike higher-energy 300–500μJ Er lasers that are typically selected when greater single-pulse energy is the primary requirement, this 20μJ 1535nm laser operates at up to 2kHz, prioritizing pulse frequency, repeated sampling and faster ranging cycles.

At 2kHz, the laser can generate up to 2,000 transmitted pulses per second. For system designers, this provides greater flexibility when developing high-frequency laser ranging, compact LiDAR and dynamic electro-optical sensing systems that benefit from repeated target interrogation rather than relying on a small number of higher-energy pulses.

The 20μJ / 2kHz Erbium Glass Laser is therefore particularly relevant when the optical link budget does not require hundreds of microjoules per pulse, but the application benefits from a significantly higher pulse repetition frequency. This design approach can support more frequent measurement opportunities, repeated sampling of moving targets and faster interaction between the laser transmitter, detector and signal-processing electronics.

Compared with a low-PRF, high-pulse-energy source, the engineering value of this 2kHz laser lies in the trade-off between lower single-pulse energy and higher temporal sampling capability. It is designed for OEM ranging architectures where pulse frequency, transmitter size and system responsiveness are more important than maximizing the energy of each individual pulse.

For LiDAR and laser rangefinder integration, the final measurement rate still depends on the complete system architecture, including detector recovery time, timing electronics, signal processing, optical path design and target conditions. The 2kHz PRF defines the available transmit-pulse frequency rather than guaranteeing 2,000 completed range measurements per second.

Engineering Advantages

2kHz High Repetition Rate for Fast, Repeated Ranging Sampling

This laser features a maximum 2kHz pulse repetition frequency (PRF), delivering up to 2,000 effective laser pulses every second. The high-frequency output well meets the operational needs of high-speed laser ranging, compact LiDAR and miniaturized electro-optical sensing systems that require continuous target sampling and fast ranging refresh cycles.

Different from conventional low-PRF 1535nm erbium glass lasers that focus on high single-pulse energy, this 20μJ 2kHz laser is specially optimized for dynamic ranging scenarios. It prioritizes high temporal sampling density and continuous pulse output stability, making it ideal for scanning LiDAR, moving-platform ranging and customized OEM systems that rely on frequent laser transmit triggering.

20μJ Nanosecond Pulse Output for Stable ToF Ranging

The module outputs consistent 20μJ pulse energy with a narrow 5–8ns nanosecond pulse width, forming high-quality pulsed laser signals that fully adapt to standard time-of-flight (ToF) ranging mechanisms.

Based on nominal pulse energy and pulse width parameters, the laser achieves a calculated peak optical power of 2.5–4kW. Its pulse design abandons excessive single-pulse energy output, and instead focuses on matching high-repetition-rate 1535nm ranging systems, ensuring stable and continuous pulse transmission as the core working performance.

In practical LiDAR and laser ranging deployment, the 20μJ pulse performance needs to be matched with supporting indicators including beam divergence, transmit optical path design, target reflectivity, atmospheric transmittance, receiver sensitivity and backend signal processing algorithms to achieve optimal overall detection results.

Note: Peak power data is calculated by nominal pulse energy divided by standard pulse width. Actual on-site peak power is subject to real measured temporal pulse profiles.

17 × 8 × 7mm Ultra-Mini Package for Strict SWaP Applications

With an ultra-small footprint of 17 × 8 × 7mm and lightweight design of ≤6g, this laser module is developed for highly integrated laser transmitter systems with extremely strict size, weight and power (SWaP) constraints.

The ultra-compact form factor brings great integration advantages for miniature LiDAR modules, UAV electro-optical payloads, portable ranging devices and micro optical sensing systems. It can be flexibly embedded into narrow internal spaces and coexist with laser drivers, transmit/receive optical assemblies, photodetectors and signal processing circuits without occupying excessive structural layout space.

For OEM developers, the ultra-light and miniaturized design effectively reduces the overall load and volume of the optical system. It reserves sufficient design margin for mechanical structure arrangement and thermal optimization, while completely retaining the core 2kHz high-frequency ranging capability.

2V / 3A Pulsed Drive Interface for Flexible OEM Secondary Development

This laser adopts a mature pulsed driving solution, with standard electrical specifications of 2V drive voltage, 3A drive current and a trigger pulse width below 0.3ms, supporting matching use with mainstream commercial pulsed laser drivers.

The standardized electrical interface is highly compatible with customized 1535nm LiDAR and laser ranging hardware circuits. Combined with MCU or FPGA control units, it can realize precise pulse triggering, timing synchronization and continuous high-frequency output control, facilitating rapid OEM integration and secondary development.

For stable long-term operation especially under continuous 2kHz high-PRF working conditions, system designers need to comprehensively verify and optimize key parameters including driving performance, trigger timing accuracy, pulse current stability, power budget and overall thermal design, so as to ensure long-term reliable operation of the laser transmitter system.

1535nm 20uJ 2KHz Eye-Safe Pulsed Erbium Glass Laser Module

20μJ 2kHz vs 40μJ 1kHz: Which High-PRF 1535nm Laser Fits Your System?

For OEM developers designing 1535nm laser ranging and LiDAR systems, the selection between20μJ 2kHz erbium glass laser and 40μJ 1kHz erbium glass laser boils down to a core engineering trade-off: higher pulse repetition frequency versus higher single-pulse energy. These two high-PRF laser models target differentiated application scenarios, enabling engineers to match laser performance precisely to actual system ranging logic and working conditions.

The 20μJ 2kHz laser is engineered for application scenarios that require dense pulse output, continuous target sampling and fast ranging update cycles. In contrast, the 40μJ 1kHz laser delivers double the single-pulse energy while maintaining a high-speed repetition rate, making it the ideal choice for scenarios that demand higher transmit power margin without sacrificing high-PRF operating performance.

Parameter

20μJ / 2kHz

40μJ / 1kHz

Pulse Energy

20μJ

40μJ

Pulse Repetition Rate

2kHz

1kHz

Max Pulse Output Frequency

Up to 2,000 pulses per second

Up to 1,000 pulses per second

Core Design Priority

Higher pulse frequency & dense sampling

Higher single-pulse energy & link margin

Typical Application Orientation

Dynamic target sampling, fast ranging refresh, high-update sensing

Longer detection distance, low-reflectivity target detection, high-loss optical scenarios

System Positioning

Ultra-compact high-frequency 1535nm ranging transmitter

High-energy high-PRF 1535nm ranging transmitter

When to Choose the 20μJ / 2kHz Laser

The 20μJ 2kHz 1535nm erbium glass laser is the optimal solution for ranging systems where sampling frequency and response speed take priority over single-pulse energy output. It focuses on high-density pulse output to support continuous and real-time target data collection.

It perfectly matches system design scenarios with the following core requirements:

  • Continuous repeated target interrogation and data sampling
  • Fast ranging cycle update and high-response sensing output
  • Dynamic ranging for moving targets and scanning sensing platforms
  • Miniaturized LiDAR transmitter and embedded ranging architectures
  • UAV payloads and portable electro-optical systems with strict SWaP constraints
  • Standard optical link budget scenarios where 20μJ pulse energy meets detection demands

With a 2kHz operating frequency, the laser achieves 2,000 effective laser pulses per second, providing system integrators with more sampling frames and temporal measurement data compared with 1kHz low-frequency laser sources, effectively improving system dynamic response and ranging continuity.

When to Choose the 40μJ / 1kHz Laser

The 40μJ 1kHz erbium glass laser is tailored for scenarios that require balanced high-PRF operation and stronger optical transmit capability. While retaining high-speed pulsed output performance, it doubles the single-pulse energy of the 20μJ model to boost system detection redundancy.

Higher 40μJ pulse energy delivers extra transmitter-side power margin, which effectively compensates for signal attenuation caused by complex atmospheric environments, long-distance optical transmission loss, low target reflectivity and limited receiver sensitivity. This significantly improves the stability and reliability of long-distance and complex-scene ranging.

The corresponding performance trade-off is a reduced maximum repetition rate of 1kHz, which is more suitable for equipment that prioritizes detection accuracy and distance coverage over ultra-high sampling frequency.

Core Selection Logic: Frequency vs. Pulse Energy

There is no absolute superior model between the two high-PRF lasers. The final selection depends on the overall design goals and optical architecture of the 1535nm laser ranging & LiDAR system.

Choose the 20μJ 2kHz laser if your system focuses on: Dense pulse output → high-frequency repeated sampling → fast ranging refresh & dynamic response

Choose the 40μJ 1kHz laser if your system focuses on: High single-pulse energy → sufficient transmit link margin → reliable high-PRF long-distance detection

In actual OEM project deployment, engineers also need to comprehensively evaluate multiple core indicators including optical link budget, laser beam divergence, transmitter optical efficiency, target surface reflectivity, receiver aperture size, detector sensitivity and timing control circuit performance.

The essential difference between the two models is not merely the gap of 20μJ pulse energy, but two differentiated high-PRF transmitter design strategies: the 20μJ 2kHz laser prioritizes high-frequency sampling and dynamic sensing performance, while the 40μJ 1kHz laser focuses on enhancing single-pulse detection capability while maintaining excellent high-speed ranging performance.

High-PRF vs High-Energy 1535nm Erbium Glass Lasers

Within the 1535nm erbium glass laser product lineup, two core engineering design paradigms dominate system integration: high pulse repetition rate and high single-pulse energy. These two design directions shape completely different laser transmitter architectures for OEM laser ranging and LiDAR systems. The 20μJ 2kHz high-PRF laser is engineered to output continuous nanosecond pulse streams, supporting dense target sampling and fast ranging refresh cycles. In comparison, 300–500μJ low-PRF 1535nm lasers prioritize ultra-high single-pulse energy to deliver superior long-distance detection performance.

Accordingly, laser selection cannot rely solely on pulse energy parameters. System integrators need to match the laser solution based on the overall ranging mechanism, application scenarios and SWaP constraints of the complete optoelectronic system.

Ideal Scenarios for 20μJ / 2kHz High-PRF Lasers

The 20μJ 2kHz 1535nm erbium glass laser serves as the optimal transmitter core for lightweight, high-update-rate ranging systems. It is tailored for application environments that value fast cyclic measurement, continuous target sampling and ultra-compact integration over extreme single-pulse energy output.

This laser model perfectly fits system designs with the following core requirements:

  • Continuous laser pulse emission and high-frequency target resampling
  • Fast ranging iteration and high real-time sensing response
  • Dynamic ranging measurement for moving targets and mobile platforms
  • Miniaturized embedded LiDAR transmitter construction
  • Lightweight electro-optical payload integration for UAV-borne and portable devices
  • Strict size, weight and power (SWaP) limited application scenarios
  • Standard link budget environments where 20μJ pulse energy fully meets ranging demands

Capable of stably outputting up to 2,000 laser pulses per second, this high-PRF laser provides system designers with abundant repeated measurement opportunities. It enables continuous tracking and data updating of target objects, delivering outstanding dynamic sensing performance.

For commercial LiDAR and dynamic electro-optical sensing equipment, high-frequency pulse iteration often brings greater practical value than high single-pulse energy. It adapts to real-time scanning and continuous detection scenarios that cannot be covered by discrete high-energy ranging pulses.

Ideal Scenarios for 300–500μJ Low-PRF Lasers

The 300μJ, 400μJ and 500μJ high-energy 1535nm Er:Glass lasers are developed for long-distance, high-stability ranging scenarios. They are the preferred solution for systems requiring strong single-pulse penetration and sufficient detection margin, even with a relatively low pulse repetition rate.

These high-energy laser modules excel in scenarios with the following design priorities:

  • Maximized single-shot transmit energy for each ranging event
  • Enhanced transmitter-side optical link budget redundancy
  • Reliable detection of low-reflectivity targets
  • Stable operation under complex atmospheric conditions and high optical path loss
  • Ultra-long-distance precision ranging and detection
  • Single-point high-precision ranging with low update frequency

In long-range laser ranging systems, sufficient single-pulse energy can effectively compensate for various signal attenuation losses. In such cases, high pulse energy plays a more decisive role in detection reliability than high repetition rate.

Core Differences Between the Two Transmitter Architectures

The gap between 20μJ 2kHz high-PRF lasers and 400μJ 10Hz low-PRF lasers goes far beyond simple power differences. They adopt targeted engineering trade-offs for completely different ranging working mechanisms and application scenarios.

Design Factor

20μJ / 2kHz High-PRF Laser

300–500μJ Low-PRF Laser

Core Design Priority

High pulse frequency & continuous repeated sampling

High single-pulse energy & long-range margin

Working Repetition Rate

Up to 2kHz high-frequency output

Low Hertz-level low-speed operation

Typical Pulse Energy

20μJ

300–500μJ

Measurement Logic

Dense and continuous pulse transmission for dynamic updating

Sparse high-energy pulses for high-precision long-distance detection

Main Application Orientation

Compact LiDAR, dynamic ranging, miniature EO sensing systems

Long-range laser rangefinders, high-link-margin detection systems

Integration Focus

Extreme SWaP optimization & high-frequency performance

Maximize transmit pulse energy & detection reliability

It is inappropriate to regard high-PRF 1535nm lasers as simplified low-power versions of high-energy ranging lasers. Essentially, this is a core engineering trade-off: high-frequency low-energy pulse streams for dynamic sampling, versus low-frequency high-energy pulses for long-distance stable detection.

System Link Budget Oriented Laser Selection Strategy

For OEM developers engaged in LiDAR and laser ranging system design, laser configuration selection needs to comprehensively evaluate multiple system-level indicators, rather than only focusing on pulse energy and PRF parameters.

Key influencing factors include effective ranging distance, target surface reflectivity, laser beam divergence, transmitter optical efficiency, atmospheric transmittance, receiver aperture size, InGaAs photodetector sensitivity, backend signal processing capability, system update rate requirements and overall SWaP limitations.

For miniaturized dynamic sensing scenarios that require frequent target sampling, fast data iteration and lightweight integration, the 20μJ 2kHz 1535nm erbium glass laser is the most cost-effective and engineering-friendly solution.

For long-distance detection scenarios requiring high anti-interference capability and sufficient optical link margin, developers should prioritize300–500μJ low-PRF high-energy Er:Glass lasers to ensure system ranging accuracy and stability in complex environments.

Application Fields

Laser Rangefinders

Ideal for handheld, miniaturized rangefinders (consumer/industrial grade) due to its ultra-compact size (17×8×7 mm), eye-safe 1535nm wavelength, and high-precision pulse performance (20 μJ, 2 KHz), enabling accurate distance measurement in outdoor/indoor scenarios.

Micro LiDAR Systems

Suited for drone obstacle avoidance, robot navigation, and micro LiDAR for smart devices, leveraging its narrow beam divergence (≤15 mrad), 0.2 mm spot diameter, and stable pulse output for high-resolution environmental sensing.

Portable Optical Sensing

Applied in portable industrial detectors, environmental monitoring sensors, and medical mini-sensing equipment, thanks to its wide temperature adaptability (-45℃~65℃) and low-voltage driving (2 V, 3 A) for easy integration into battery-powered devices.

Consumer Electronics

Integrated into smart wearables, outdoor gear, and smart home sensing modules, utilizing its lightweight (≤6 g) and compact design to add precision ranging/sensing functions without occupying excessive space.

Security & Surveillance

Used in laser-based intrusion detection and perimeter security systems, benefiting from its eye-safe operation, long-term stability, and resistance to harsh environmental conditions for reliable 24/7 monitoring.

 

1535nm 20uJ 2KHz Eye-Safe Pulsed Erbium Glass Laser Module

1535nm High-PRF Ranging Solution

A 20μJ 2kHz 1535nm Erbium Glass Laser is only one component of a high-repetition-rate laser ranging system. Actual ranging performance depends on how the laser source works together with the pulsed laser driver, transmitting optics, receiving optics, InGaAs detector, timing electronics and signal-processing architecture.

For OEM projects, these components should be evaluated as a complete optical and electronic chain rather than selecting the laser by pulse energy or repetition rate alone.

20μJ / 2kHz Er:Glass Laser → Pulsed Laser Driver → Beam Collimation Optics → Target → Receiving Optics → InGaAs Detector → Timing & Signal Processing → Distance Output

20μJ / 2kHz Laser Source

The 1535nm high-PRF laser provides the optical transmit pulse for the ranging system. With 20μJ pulse energy, 5–8ns pulse width and up to 2kHz repetition rate, it is positioned for architectures that prioritize frequent transmit events and repeated target sampling rather than high single-pulse energy.

Laser selection should be matched to the required ranging distance, target reflectivity, transmitter efficiency, receiver sensitivity and measurement frequency.

Pulsed Laser Driver and Timing Control

The Er:Glass laser requires a compatible 2V, 3A pulsed laser driver with a drive pulse width below 0.3ms.

In a complete ranging system, the driver converts the control command into the electrical pulse required by the laser while maintaining the required repetition rate and timing sequence. MCU- or FPGA-based electronics can be used at the system-control level to coordinate laser triggering, detector timing and subsequent signal processing through the appropriate driver circuitry.

For 2kHz laser operation, driver capability and thermal behavior should be evaluated together with the laser rather than treated as independent design parameters.

Beam Collimation and Transmitting Optics

The raw output from the 1535nm Erbium Glass Laser must be matched to the transmitting optical system according to the required beam characteristics.

Collimation or beam-expansion optics can be used to manage the outgoing beam for the intended ranging architecture. Optical design decisions should consider the laser's output beam characteristics together with aperture size, optical transmission, alignment tolerance and required far-field divergence.

For OEM integration, this stage directly affects how efficiently the available 20μJ pulse energy is delivered toward the target.

Receiving Optics and InGaAs Detection

After the transmitted pulse reaches the target, only a portion of the reflected optical energy returns to the ranging system. The receiving optics collect this return signal and direct it toward a detector suitable for operation around 1535nm, commonly based on InGaAs detection technology.

Receiver performance depends on factors such as receiving aperture, optical transmission, field of view, detector sensitivity, noise characteristics and target reflectivity.

This is why the required laser pulse energy cannot be determined independently from the receiver architecture: a 20μJ transmitter must be evaluated as part of the complete optical link budget.

Timing, Signal Processing and Distance Calculation

The electrical signal generated by the detector is processed by the ranging electronics to identify the returned laser pulse and determine its time of flight.

For a time-of-flight ranging architecture, distance is derived from the interval between the transmitted and received pulse:

Distance = (Speed of Light × Time of Flight) / 2

With a laser PRF of up to 2kHz, the transmitter can provide up to 2,000 optical pulse events per second. The actual ranging update rate depends on the detector, timing electronics, signal-processing algorithm, target conditions and overall system architecture.

OEM Support from Laser Source to Ranging Architecture

For customers developing 1535nm LiDAR, high-frequency laser rangefinders or compact electro-optical ranging systems, laser selection is often only the first engineering decision.

Based on project requirements, we can support the evaluation of:

20μJ / 2kHz 1535nm laser source selection

pulsed laser driver matching;

transmitting and beam-collimation optics;

receiver and InGaAs detector integration;

mechanical and electrical interface requirements;

timing and system-level integration;

complete 1535nm laser ranging module architecture.

Customers can provide their required ranging distance, target characteristics, repetition rate, receiver configuration, available installation space and operating environment so that the laser source and surrounding ranging architecture can be evaluated together.

This system-level approach helps determine whether the 20μJ / 2kHz high-PRF laser is appropriate for the application or whether a different pulse-energy and repetition-rate configuration would provide a better engineering fit.

FAQ

1. What are the core advantages of the 20μJ 2kHz 1535nm erbium glass laser?

This 20μJ 2kHz 1535nm laser features an ultra-high 2kHz pulse repetition rate, delivering up to 2000 laser pulses per second. Different from high-energy low-PRF laser solutions, this module is optimized for high-frequency ranging and compact LiDAR systems. It supports continuous target sampling and fast ranging update cycles, while maintaining ultra-small size and lightweight features, perfectly matching SWaP-constrained embedded electro-optical sensing platforms.

2. Is 20μJ pulse energy sufficient for practical laser ranging and LiDAR applications?

The applicability of 20μJ pulse energy depends on the overall system optical link budget, rather than a single parameter. Multiple key factors determine final ranging performance, including target reflectivity, detection distance, laser beam divergence, transmitter optical efficiency, receiver aperture, InGaAs detector sensitivity and atmospheric transmission conditions. Tailored for high-update dynamic sensing scenarios, the 20μJ high-PRF design delivers excellent comprehensive performance for compact LiDAR and short-to-medium distance continuous ranging systems.

3. What is the practical difference between 20μJ 2kHz and 40μJ 1kHz laser models?

The two 1535nm laser models represent a classic engineering trade-off between pulse repetition frequency and single-pulse energy. The 20μJ 2kHz laser prioritizes high-frequency pulse output, focusing on dense target sampling and fast ranging response for dynamic sensing. In contrast, the 40μJ 1kHz laser doubles the single-pulse energy to provide higher transmit-side link margin, suitable for scenarios requiring stronger anti-interference and longer detection distance while retaining high-PRF operating capability.

4. Can the 20μJ 2kHz laser be applied to LiDAR and moving-target ranging systems?

Thanks to its maximum 2kHz high repetition rate, this laser is highly suitable for compact LiDAR systems and dynamic moving-target ranging scenarios. The high-frequency continuous pulse output enables repeated interrogation and real-time data sampling of moving targets, effectively improving system dynamic response and measurement continuity. The final ranging and tracking performance needs to be matched with supporting receiver circuits, timing control systems and signal processing algorithms to achieve optimal results.

5. What drive conditions are required for the 20μJ 2kHz laser module?

This 1535nm laser requires a matched pulsed laser driver with standard electrical specifications of 2V voltage, 3A current and a drive pulse width below 0.3ms. It supports stable high-frequency triggering up to 2kHz. System developers can build synchronous control through MCU or FPGA circuits to achieve precise pulse triggering and continuous high-speed output, which is friendly for customized OEM secondary development.

6. What is the actual peak optical power of the 20μJ laser?

Equipped with 20μJ nominal pulse energy and 5–8ns narrow pulse width, the laser achieves a calculated peak optical power ranging from 2.5kW to 4kW. This data is derived from nominal pulse energy and pulse width calculation. The actual output peak power is subject to real tested temporal pulse profiles under actual working conditions.

7. Is the 1535nm laser eye-safe for outdoor application?

The 1535nm wavelength is widely adopted for eye-safe laser ranging architectures in the industry. However, laser safety classification is not determined by wavelength alone. The final system safety level needs comprehensive evaluation based on complete optical path design, beam divergence, output pulse parameters, emission aperture and actual application scenarios, complying with standard laser safety specifications for finished outdoor equipment.

Hot Tags: 1535nm 20uj 2khz eye-safe pulsed erbium glass laser module, China, manufacturers, suppliers, factory, customized, wholesale, best, cheap, professional, for sale, near me

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag